One HXD-V1 dries the hydrogen of up to five HXB-V1 units. This chapter covers how they are combined in one rack and connected.
- Units1 to 5 × HXB-V1
- Max. flow2.5 Nm³/h
- Rack42U
How to read this chapter
First timeLook at the rack layout and the sizing.
Done this beforeGo to the checklist.
On this pageStandard rack layout
Standard rack layout#
In the standard HydroXpand rack, five HXB-V1 units (6U each) sit above one HXD-V1 (6U) in a 42U rack. The dryer is at the bottom.
- The HXB-V1 hydrogen outlet connects straight to H2 IN of the dryer.
- Oxygen and vent lines of the HXB-V1 units are separate from the dryer lines. Do not join them.
- Each unit has its own power cord. Plan one supply circuit per unit, as given in the HXB-V1 handbook and in this handbook.
- Keep the front and rear of the rack free for access and air flow.
Sizing#
| HXB-V1 units | Note |
|---|---|
| 1 to 5 | One HXD-V1 covers the full range up to 2.5 Nm³/h |
| More than 5 | Use one HXD-V1 per group of up to five HXB-V1 units |
Checklist#
- The HXB-V1 hydrogen outlet is connected to H2 IN of the dryer.
- All vents, from the HXB-V1 units and the dryer, run to a safe place outdoors without valves.
- The dryer is switched on before the HXB-V1 units start, and the HXB-V1 units are stopped before the dryer is switched off.
What this chapter is based on
- HXD-V1 datasheetPDF · 3.2 MB
- HXD-V1 outline drawingPDF · 368 KB
- First start checklistPDF · 61 KB
- Routine check sheetPDF · 66 KB
- Maintenance logPDF · 49 KB
- HXD-V1 user manualPDF · 2.7 MB
Was this page helpful?
Thank you. We read every answer.
Tell us what was missing and we will fix this page. Tell us what was missing →
Ask the engineer who built it
If your case is not covered here, send us the operating condition and what you observed. The engineer who designed the system answers directly.