What to check and how often, and what HydroXpand does for you. The adsorbent is sealed and needs no replacement.
- AdsorbentSealed · no replacement
- DailyLeaks · vents · readings
First timeCopy the check lists into your own check sheet.
Done this beforeGo to service by HydroXpand.
On this pageBefore any work
Before any work#
Check lists#
Daily, or each shift#
- No leaks at the front panel fittings and the tubing.
- Vent and drain lines intact and not blocked.
- Outlet dew point and operating pressure in the normal range. No active alarms.
Monthly#
- Rear fans running and air openings free of dust.
- Dew point trend. A slow rise over weeks is a reason to contact HydroXpand.
- Drain events. A clear increase points to more water coming from upstream.
Yearly#
- Leak check of all connections at operating pressure.
- Check the dew point sensor or analyser against a reference, as its maker recommends.
- Check the power cord, the earth connection and the network cable.
Service by HydroXpand#
Internal parts such as filters, valves and sensors are serviced by HydroXpand or a partner we authorise. Do not open the pressure parts or replace internal components yourself.
When you contact us, please send the serial number, the firmware version, the operating hours and an export of recent events.
What this chapter is based on
- HXD-V1 datasheetPDF · 3.2 MB
- HXD-V1 outline drawingPDF · 368 KB
- First start checklistPDF · 61 KB
- Routine check sheetPDF · 66 KB
- Maintenance logPDF · 49 KB
- HXD-V1 user manualPDF · 2.7 MB
Thank you. We read every answer.
Tell us what was missing and we will fix this page. Tell us what was missing →
Ask the engineer who built it
If your case is not covered here, send us the operating condition and what you observed. The engineer who designed the system answers directly.