← ProductsSystems

HXB-V1 2 kW turnkey AEM electrolyzer system for 1 kg of hydrogen per day

AvailableCE Declaration of Conformity (LVD, EMC, RoHS)

HXB-V1 is a turnkey system that combines the anion exchange membrane (AEM) stack, power, circulation, temperature control and safety functions in one 19-inch 6U rack, producing 1 kg of hydrogen per day on site for connection to downstream site equipment.

The HXB-V1 is a 2 kW turnkey hydrogen generator that integrates the HXS-2 stack with power, electrolyte circulation, gas separation and safety in a single 19-inch 6U rack, rated at 500 L/h (1 kg/day) and available to order. It ships eight weeks from PO acceptance.

2 kW system
Rated production500 L/h · 1 kg/day
Production pressure0 / 10 barg

Chosen when ordering

OPTIONH₂ purity≥ 99.999%

With dryer

Operating power2.4 kW

BOL · 50 A

Who it is for

A complete 2 kW system that produces hydrogen on site

HXB-V1 is the 2 kW electrolyzer as a complete system; if you only need the 2 kW stack for your own BoP, that is the HXS-2. Installation feasibility depends on power, water, ventilation, outlet piping and the boundary to purification, drying, compression and storage.

Choose this product when
  • Sites using modest volumes of hydrogen continuously where delivery logistics are a burden
  • Demonstration or research projects that use remote access to the computer running the desktop app for off-site monitoring and control
  • Configurations that connect downstream to drying, storage and compression
HXB-V1

Using HXB-V1 as a research and pilot platform

Review stack replacement, operating controls and data access against your test plan.

Can we run our own catalyst or MEA?
The stack is removable, disassemblable and replaceable. Customer MEA compatibility and target operating points are reviewed before order. It is a 23-cell HXS-2; opening the cells and changing the MEA is in the HXS-2 handbook under Maintenance.
How do we get the data out?
The control app logs at 1 s and exports CSV. For a supervisory system use MQTT/JSON or Modbus TCP (PLC, SCADA). RTU and ASCII are not supported.
What can we set ourselves?
Voltage, current, electrolyte temperature and electrolyte flow. Operating current 15–67 A, 50 A recommended. Outlet pressure, 0 or 10 barg, is chosen at order.
What protects the test?
H₂ detection, interlocks and an electrolyte-tank pressure switch that stops the unit. The manual emergency stop is Emergency STOP in the control app; there is no separate button on the unit.
SITE CONNECTION

What HXB-V1 covers and what the site provides

HXB-V1 integrates the core functions needed to produce hydrogen. Storage, compression and end-use equipment are configured separately for the site.

CUSTOMER01

Power and feedwater

200–240 V AC single phase · Type II feedwater

HYDROXPAND02

HXB-V1

Integrated stack, power, circulation, controls and safety

OPTION03

Hydrogen drying

Not standard · modular product in development

CUSTOMER04

Storage, compression and use

Downstream equipment for the site application

HYDROXPAND

Included supply scope

  • Integrated 2 kW stack, power supply, electrolyte circulation, temperature control, automatic water refill and safety logic
  • Desktop control app and an MQTT over Ethernet (JSON) interface
  • Dryer not included as standard · modular dryer in development · partner product can be recommended when needed immediately
  • Dimensional data and an exterior/enclosure-only STEP model available for installation planning
CUSTOMER

Customer preparation

  • 200–240 V AC single phase 50/60 Hz (total consumption approx. 2.4 kW)
  • A feed-water tank, recommended quality ASTM D1193 Type II (1.0 µS/cm or below at 25 °C), maximum 30 µS/cm
  • H₂ and O₂ outlet, vent and drain piping, plus use, storage or compression equipment
  • An indoor 5–45 °C installation environment, ventilation and site hydrogen safety measures
COMPONENTS AND BOPWhat attaches on either side of HXB-V1The BoP is built in, so only upstream and downstream are left to decide
Integrated operation

One unit covers the essential operating loop

Review the integrated hardware first. Open the software views only when you need the detailed daily workflow.

System layout · exploded view
System layout · exploded view
INTEGRATED

The 6U unit combines the core operating functions

  • AEM stack and DC power
  • Electrolyte circulation and temperature control
  • Automatic water refill and operating sensors
  • Control and safety logic
Open the operating software views3 views
OPERATIONS SOFTWARE

The daily operating loop in three views

Monitor the system, inspect the process state and define an operating protocol. Additional software views are available during a technical review.

Control app · Dashboard
Control app · Dashboard
HXB-V1

Before you ask for a quote

Review supply scope, installation needs and commercial terms. Share your output, purity and pressure requirements so we can prepare a suitable configuration and quotation.

Included and not included
Included: the unit (stack, circulation pump, power supply and controller built in), control app, handbook, CE Declaration of Conformity, 12-month warranty. Not included: water treatment, hydrogen dryer, compressor, storage, site piping, installation work, control PC.
Purity and dryer
99 % without a dryer (10 barg, water-saturated). ≥ 99.999 % with a dryer. Our own dryer HXD-V1 is scheduled for Q4 2026 and taken on pre-order; if you need drying now, give us the dew point, flow and pressure and we quote a configuration. Applications that accept 99 %, such as combustion and some process use, can be supplied now.
Pressure
Choose 0 or 10 barg at order; we fit the matching relief valve before shipment. A 10 barg unit always builds up to 10 barg in operation. 35 barg is under verification and supplied by agreement.
Feed water and electrolyte
Deionised water ≤ 1.0 µS/cm recommended, up to 30 µS/cm in service. Consumption 0.55 L/h (50 A, 60 °C). We recommend sourcing water treatment locally and send a recommended specification on request. Electrolyte KOH 0.1–1 M (0.1 M recommended, about 5 L initial fill) is supplied by the customer.
Delivery terms and shipping
EXW Hwaseong, Korea. Crated and handed to a freight forwarder. Freight on the quotation is an estimate; DAP and DDP are quoted on request. Duties, VAT and local certification costs are borne by the importer.
Payment, lead time, validity
T/T 100 % in advance: proforma invoice, production starts on receipt of funds, shipment 8 weeks later. USD by default, EUR invoicing available. Quotations are valid 30 days. Units are built to order; we keep no demo stock.
Warranty and support
12 months from shipment (from acceptance where an acceptance procedure applies; consumables excluded), return-to-base. Support runs installation, start-up and maintenance training in Korea, then remote support during operation, then return-to-base repair. An MEA replacement service is available.
Certification and track record
The CE Declaration of Conformity can be downloaded from the handbook. There is no UL/NRTL listing, so check local inspection requirements for North American sites. Operating evidence and test conditions are provided in the specifications and related technical resources.
Price
Depends on quantity, configuration and Incoterms, so it is issued as a quotation. Include output, purity and pressure so we can review configuration and supply terms.

This is a summary of standard supply terms. Configuration, lead time and commercial terms are confirmed in your quotation.

Request a quotation
Specifications

HXB-V1 specifications and supply terms

The specification table, support terms and review documents.

Production performance5 items
H₂ production500 L/h (approx. 1 kg/day)
Energy use (kW)2.4 kW (BOL · 2.0 stack + 0.4 BoP)
Energy use (kWh/Nm³)4.8 (BOL)
Energy use (kWh/kg-H₂)Stack 44 · system 54 (the difference, about 10 kWh/kg, is the BoP)
Operating current15–67 A (50 A recommended)
Hydrogen purity & pressure3 items
H₂ purity @ 0 barg98–99% (no dryer) · ≥ 99.999% (with dryer)
H₂ purity @ 10 barg99% (no dryer) · ≥ 99.999% (with dryer)
H₂ pressure0 or 10 barg · chosen at order (relief valve); 35 barg by agreement
Power & water5 items
Power supply200–240 V AC · 50/60 Hz · single phase
Water conductivityRecommended ASTM D1193 Type II (≤1.0 µS/cm) · in-service ≤30 µS/cm
Water consumption0.55 L/h (50 A · 60 °C)
Feed water top-upBuilt-in gear pump refills automatically
ElectrolyteKOH 0.1–1 M · circulation 2–5 L/min
Installation7 items
Ambient temp5–45 °C
IP ratingIP 20
Dimensions482 × 647 × 266 mm (6U)
Weight51.3 kg
Fluid connectionsH₂O · H₂ · O₂ · VENT · DRAIN 1/4″ double-ferrule
Power inletC20 AC inlet (C19 cable)
Installation clearanceFront ≥ 300 mm · rear ≥ 400 mm
Controls & communications4 items
ControlDesktop app (MQTT/Ethernet)
Direct controlVoltage · current · electrolyte temperature · electrolyte flow
Stack handlingRemovable · disassemblable · replaceable
Telemetry1 s interval · 8 external control variables · Modbus TCP supported (not RTU)
Safety & warranty2 items
SafetyH₂ detection · emergency stop (control app) · interlocks · electrolyte tank pressure switch auto-stop
Warranty12 months from shipment, or from acceptance where an acceptance procedure applies (consumables excluded)
How to cite in a paper1 item

Use the line below in the Methods section when reporting the material source.

AEM water electrolysis system, 2 kW, 500 L/h (HXB-V1, HydroXpand Inc., Republic of Korea)
Specification
19-inch 6U rack with the 23-cell HXS-2 stack, 0 or 10 barg outlet
Test condition
0.1 M KOH, 50 °C

Ask [email protected] if the lot number is required.

Support, lead time and commercial terms3 items
Support & warranty

One-year warranty under standard operating conditions. Routine checks cover feedwater, leaks and operating data; KOH is replaced by condition rather than on a fixed interval. A returned stack can be refurbished by replacing only the MEA and reusing the hardware.

Lead time & status

Available · 8 weeks from PO acceptance

Commercial terms & origin

EXW basis; DAP and other terms by agreement. Country of origin is the Republic of Korea, with certificate of origin provided.

Pricing depends on quantity and Incoterms, so it is issued as a quotation. Before asking for one, compare five years of buying cylinders against making the same hydrogen on site.

Cost vs cylinders calculator
Before you order

HXB-V1: questions before you order

Minimum order, lead time, formats and how pricing works. The full FAQ covers operating and integration questions.

How do I buy the HXB-V1?

HydroXpand sells it directly. Send the hydrogen flow you need, operating hours, outlet pressure (0 or 10 barg) and the installation site through the enquiry form or to [email protected]; we return a quotation with price, lead time and Incoterms, and the lead time counts from the day we accept your purchase order.

What are the lead time and the warranty?

It ships eight weeks from PO acceptance. The warranty is one year under standard operating conditions, counted from the ship date or, where an acceptance procedure applies, from the acceptance date.

What power supply does it need, and how much hydrogen does it make?

It runs on 200–240 V AC single-phase 50/60 Hz and draws about 2.4 kW in total. Hydrogen output is 500 L/h (0.5 Nm³/h, 1 kg/day) and system energy consumption including BoP is 54 kWh per kg of hydrogen.

Is a dryer included, and what purity do I get?

The standard configuration does not include a dryer. Without one the outlet hydrogen is 98–99% at ambient pressure and 99% at 10 barg; with a dryer we have verified ≥ 99.999% under our test conditions. Our modular dryer HXD-V1 is taking pre-orders, and until then we source a dryer matched to your conditions.

How much does it cost?

Price depends on quantity, configuration (outlet pressure, dryer) and Incoterms, so it is issued as a quotation. As a 19-inch rack unit it scales by adding units: five stacked units make a 10 kW class system of about 5 kg per day.

What certification and control interfaces does it have?

HXB-V1 carries a manufacturer's EU Declaration of Conformity and CE marking (LVD, EMC, RoHS; a self-declaration, not third-party certification). Control is Ethernet MQTT with JSON payloads, and PLC or SCADA systems connect over Modbus TCP.

What are the commercial terms and the country of origin?

EXW is the base term and other Incoterms such as DAP are available. The country of origin is the Republic of Korea; a certificate of origin is provided, so FTA preference may apply in countries that have an FTA with Korea.

Enquiry

Installation and downstream review

Send the operating hours, purity, pressure, power and downstream plan, and we will review the installation conditions.