Troubleshooting

HXD-V1 · updated 2026-11-11

A find-by-symptom table, cause-by-cause checks for dew point, pressure, regeneration temperature and drains, the control app's alarm list (ES, FS, WA) and what to send us.

Common symptoms and what to check first, and the control app's alarm list. If the cause is not clear, stop the system and contact HydroXpand.

On this pageWhere to start

Where to start#

  1. Look at Status and MQTT at the top of the app. If it shows OFFLINE, check power and Ethernet first.
  2. Read the code of any active alarm on the Alarms & Events screen, find the same code in the Alarms section below and follow the action.
  3. If there is no alarm, read the inlet and outlet pressures, tower temperatures and dew point on the P&ID screen and compare them with the Find by symptom table.
  4. If the cause is not clear, stop the system, gather the items under What to send us and contact HydroXpand.

Find by symptom#

Find the symptom in the table below. Dew point, pressure, regeneration temperature and drains are covered cause by cause in symptoms A to D after the table.

SymptomPossible causeWhat to do
Outlet dew point too high after startThe adsorbent took up moisture before start-upSend the product to vent and let the unit complete one or more full cycles
Outlet dew point rises during operationHydrogen at H2 IN warmer or wetter than usual. Regeneration cycle set too longCheck the upstream units and the room temperature. Check the cycle setting
Pressure does not reach 10 barg, or the status shows STANDBYA leak, or the HXB-V1 units are not producing enough hydrogen. The unit waits when inlet pressure falls below 8.5 bargLeak-check the connections. Check the HXB-V1 units. The unit carries on automatically once inlet pressure is back at 9.5 barg or above
Frequent drain eventsMore water carried from upstream than usualCheck the HXB-V1 units and the inlet line for water collecting at low points
No flow at PURGE during regenerationVent line blocked or closedStop the system. Clear the vent line. Never fit a valve in it
Unit stops with a liquid leak alarmLiquid has collected inside the unitKeep it stopped and switched off. Contact HydroXpand
Heater does not heatOverheat trip open, or no power to the heaterLet the unit cool. If it repeats, contact HydroXpand
No connection over EthernetCable, network settingsCheck the cable and the IP settings on the control PC

Symptom A. The outlet dew point is too high#

Just after start-up
The adsorbent took up moisture while the unit was stored or stopped. Send the product to vent and let the unit complete one or more full cycles. If it is still high after that, work through the items below.
The incoming hydrogen is warmer or wetter than usual
Warning WA_08 appears when the adsorber inlet gas temperature exceeds 80 °C. Check the operating temperature of the HXB-V1 units, the room temperature, and whether water is collecting anywhere in the inlet line.
The regeneration settings have changed
A longer cycle or a lower regeneration temperature sends the tower back on line less dry. Compare the settings with the defaults under regeneration settings.
Regeneration is not finishing
Hydrogen should always leave through PURGE during regeneration. If the PURGE vent is blocked, the water driven off the tower cannot be carried out. Stop the system and clear the vent line. If the tower is not heating, see symptom C.
Only your own analyser reads high
The same water content reads as a higher dew point at higher pressure. About 5 ppm of water reads about -65 °C at atmospheric pressure and about -47 °C at 10 barg. First check which pressure your analyser's reading refers to.

Symptom B. Inlet pressure is low or the unit keeps going to STANDBY#

Not enough hydrogen from the HXB-V1 units
Below 8.5 barg at the inlet the dryer waits in STANDBY, and it carries on by itself once the pressure is back at 9.5 barg or above. First check that no HXB-V1 is switched off or stopped on an alarm.
A connection is leaking
Warning WA_07 appears when the online tower's pressure is low. Leak-check the connections from the HXB-V1 units to H2 IN, and after H2 OUT, with leak detection fluid.
The pressure reading looks wrong
If the reading jumps or sticks at one value, suspect the sensor. A reading outside -1 to 30 barg stops the unit with FS_06. Keep it stopped and contact HydroXpand.
The pressure is too high instead
Above 15 barg the unit makes an emergency stop (ES_05). Check that the line after H2 OUT and the vents are not blocked and that no valve in them is closed.

Symptom C. The tower does not heat, or switching is late#

The regeneration temperature is not reached within the heating time
If the regeneration temperature is not reached by the end of the heating time, the unit stops with FS_09. If the heater gets no power during heating, it is FS_01. Keep the unit stopped and contact HydroXpand.
The overheat trip has opened
The overheat trip cuts heater power directly, independently of the controls. Let the unit cool and check again; if it repeats, contact HydroXpand. Warning WA_04 appears if the heater signal drops out 10 times or more in an hour.
The switching delay (IDLE) lasts a long time
The towers swap only once the regenerated tower has cooled to 40 °C or below. The tower is cooled by the hydrogen flowing out through PURGE, so a blocked PURGE vent slows cooling. Check the vent line.
Manual switching is refused
If the regenerated tower has not cooled yet, or the conditions are not met, the request is refused with warning WA_05. Check the current step and try again after the switching delay.

Symptom D. Frequent drains or a water-related alarm#

More water is arriving from upstream
The separator collects water carried with the hydrogen and empties it to DRAIN. If the drain runs more often than usual, check the HXB-V1 units and the low points of the inlet line for collecting water.
The level stays high
Warning WA_03 appears when the separator level stays high for ten minutes; WA_02 means the drain valve did not move as commanded. Check the DRAIN line and the liquid trap for blockages.
Liquid has been detected inside the unit
This is the emergency stop for a liquid leak (ES_01). Switch off and treat the liquid as alkaline. Do not restart before the cause is found; contact HydroXpand.

Alarms#

Alarms appear on the control app's Alarms & Events screen and in the safety snapshot on the home screen, with the code, the app message, the measured value and the limit. Emergency stops (ES) and fault stops (FS) stop the unit; warnings (WA) keep it running and tell you. Limits in the tables are the default settings.

Emergency stop (ES)#

App messageLabelMeaningWhat to do
Water leak detected in enclosureES_01ELS401Liquid was detected inside the enclosureSwitch off and treat the liquid as alkaline. Do not restart until the cause is found
Heater contactor welded (main contact stuck closed)ES_02MC401The heater contactor is stuck closed and cannot cut heater powerOpen the panel breaker and contact HydroXpand
Adsorber bed temperature critical highES_03TE201/202A tower is 30 °C or more above the regeneration temperature (250 °C at most)Let the unit cool and contact HydroXpand. Do not open it while hot
System pressure critical highES_05PT101PT301System pressure is above 15 bargStop the HXB-V1 units and check that H2 OUT and the vent lines are not blocked

Fault stop (FS)#

App messageLabelMeaningWhat to do
Heater not energized - feedback lostFS_01HTR201HTR202The heater is not powered during heatingKeep the unit stopped and contact HydroXpand
Heater contactor not energizedFS_02MC401The heater contactor does not closeKeep the unit stopped and contact HydroXpand
Heater contactor auxiliary contact mismatchFS_03MC401The heater contactor's auxiliary contact does not matchKeep the unit stopped and contact HydroXpand
Switching valve feedback mismatchFS_04SV201A–202BA switching valve did not move as commandedKeep the unit stopped and contact HydroXpand
Temperature sensor faultFS_05TE102TE201TE202A temperature reading is outside -50–400 °CKeep the unit stopped and contact HydroXpand
Pressure sensor faultFS_06PT101PT301A pressure reading is outside -1–30 bargKeep the unit stopped and contact HydroXpand
Dew point sensor faultFS_07AT301The dew point reading is outside -100–50 °CKeep the unit stopped and contact HydroXpand
Product dew point out of specification (stop)FS_08AT301The outlet dew point has stayed above -65 °C for ten minutesSend the product to vent. Check the upstream units and the regeneration settings, and contact HydroXpand if it repeats
Regeneration failed - target temperature not reachedFS_09TE201/202The tower did not reach the regeneration temperature within the heating timeKeep the unit stopped and contact HydroXpand

Warning (WA)#

App messageLabelMeaningWhat to do
Ventilation fan not runningWA_01FAN401–403A ventilation fan is not runningCheck that the rear air openings are clear. Contact HydroXpand if it persists
Drain valve feedback mismatchWA_02SV101The drain valve did not move as commandedCheck that the DRAIN line and the liquid trap are not blocked
Separator liquid level high persistsWA_03LS101The separator level has stayed high for ten minutesCheck the DRAIN line, the liquid trap and how much water comes from upstream
Heater feedback dropping frequentlyWA_04HTR201HTR202The heater feedback dropped out 10 times or more within an hourContact HydroXpand
Manual adsorber switch rejectedWA_05A manual tower switch was refused because the conditions were not metCheck the current step and try again after the switching delay
Product dew point highWA_06AT301The outlet dew point is above -70 °C (early warning)Watch the dew point trend. If it stays above -65 °C the unit stops with FS_08
Adsorbing tower pressure lowWA_07PS201APS201BPressure in the online tower is lowCheck the inlet pressure and leak-check the connections
Adsorber inlet temperature highWA_08TE102The gas entering the adsorbers is above 80 °CCheck the upstream units, the room temperature and the inlet line
Telemetry not receivedWA_09The control app is not receiving data from the unitCheck the Ethernet cable and the unit's power
Heartbeat not received by deviceWA_11The unit is not receiving the control app's heartbeatCheck that the app is running on the control PC and the network is connected

What to send us#

  • Serial number and firmware version
  • When the symptom first appeared, with the operating pressure and dew point at the time
  • An export of recent events
  • How many HXB-V1 units are connected, and photos of the pipework

What this chapter is based on

Resource library →

Was this page helpful?