HXS-0 AEM test cell & short stack (1–25 cm²)

Available

MEA test hardware designed for evaluating customer-supplied catalysts, electrodes and membranes. Choose the active area and cell count, and compare them in the same hardware.

The HXS-0 is a made-to-order test cell with a selectable 1–25 cm² active area, available from a single cell up to a 20-cell short stack. It ships four weeks from PO acceptance once the active area, cell count and flow field are fixed.

1–25 cm² test cell
Active area1–25 cm²
Configuration1–20 cells
Standard flow fieldSingle-serpentine
MEAStandard excludes · optional
Who it is for

A test cell built around your own MEAs and test equipment

HXS-0 is electrolyzer test cell hardware: it sets active area through the gasket window and scales from a single cell to a short stack. The key is to define the boundary between cell hardware, MEA and your power and circulation equipment.

Choose this product when
  • Research screening catalyst, membrane and electrode combinations at cell level
  • Defining scale-up conditions from single cell to short stack
  • Comparing performance with MEAs you fabricate yourself
TEST CONFIGURATION

Define the test through four configuration choices

Set the active area, cell count, MEA and available test equipment to define the required hardware.

CATALOGUE01

Active area

Select 1–25 cm² through the gasket window

CATALOGUE02

Cell count

Single cell to 20-cell short stack

CUSTOMER03

MEA and electrodes

Own or third-party MEA, or HXP electrodes

CUSTOMER04

Test station

Power, circulation, temperature control and data logging

HYDROXPAND

Included supply scope

  • Selectable 1–25 cm² active area, from a single cell to a 20-cell short stack
  • SUS316L end plates, nickel-based bipolar plates, PTFE gaskets and a single-serpentine flow field
  • MEA excluded as standard · MEA with HXP-an, HXP-ca and membrane available on request
CUSTOMER

Customer preparation

  • Power supply (a programmable unit is recommended for wide voltage and current sweeps)
  • Electrolyte circulation, temperature control and data logging
  • MEA or electrodes (our HXP-an and HXP-ca can be used)
COMPONENTS AND BOPWhat HXS-0 evaluation needs around itUpstream, in-stack and downstream to run single cell and short stack work
Test results

i-V curve from a 4 cm² test configuration

The label on each chart says whether it is measured, test or design-target data. Test conditions are in each chart caption.

TEST DATA01

A catalogue i-V curve from a 4 cm² test configuration, clearly separated from the selectable product area range.

Catalogue i-V performance curve · 4 cm² · HXP-an · 1 M KOH · 80 °C · 2.00 V at 6.6 A/cm²

Catalogue i-V performance curve · 4 cm² · HXP-an · 1 M KOH · 80 °C · 2.00 V at 6.6 A/cm²
Specifications

HXS-0 specifications and supply terms

The specification table, support terms and review documents.

Complete product specifications14 items
UseResearch/evaluation single cell / short stack
Active area1–25 cm² (set by the gasket window)
ConfigurationSingle cell up to a 20-cell short stack
ElectrodesHXP-an · HXP-ca
Operating conditionUp to 80 °C · atmospheric pressure
StructureAnode-side electrolyte circulation
BuildAvailable · made to order after active area, cell count and flow field are fixed
MaterialsSUS316L end plates · nickel-based bipolar plates · PTFE gaskets
Flow fieldSingle-serpentine standard · custom flow field available for the test objective
FasteningM6 · no press required · tightening sequence and torque supplied in the assembly guide · electrode terminals M4 · 1.5–2.0 N·m
Fluid connection1/4″ double-ferrule
MEA compatibilityMEA excluded from the standard supply · HXP-an, HXP-ca and membrane MEA available on request
Dimensions114 × 85.6 × 136 mm
Weight4 kg
How to cite in a paper1 item

Use the line below in the Methods section when reporting the material source.

AEM electrolysis test cell (HXS-0, HydroXpand Inc., Republic of Korea)
Specification
1–25 cm² active area, SUS316L end plates, nickel-based bipolar plates

Ask [email protected] if the lot number is required.

Support, lead time and commercial terms3 items
Consumables & support

Consumables such as gaskets are supplied separately, and the active area and cell count are fixed in the quotation.

Lead time & status

Available · made to order · 4 weeks after active area, cell count and flow field are fixed and the PO is accepted

Commercial terms & origin

EXW basis; DAP and other terms by agreement. Country of origin is the Republic of Korea, with certificate of origin provided.

Pricing depends on quantity and Incoterms, so it is issued as a quotation. Before asking for one, compare five years of buying cylinders against making the same hydrogen on site.

Cost vs cylinders calculator
Enquiry

Test cell configuration

Send the active area, cell count, MEA and available equipment, and we will define the required configuration.