Maintenance

HXS-30 · updated 2026-10-01

Why not to open the stack and how MEAs are replaced, the check lists, when to change the electrolyte, cleaning, and reading the trend.

The check lists, when to change the electrolyte, how to clean, and how to read the stack voltage trend.

The intervals here are guidance. Actual frequencies depend on run hours, load profile, ambient conditions and electrolyte condition.

  • Electrolyte changeNo fixed interval; judged by condition
  • Record at minimumVoltage · current · flow · temperature
  • Before any workCurrent to 0 A · DC supply isolated
How to read this chapter

First timePrint the check lists and remember the three criteria in the electrolyte section.

Done this beforeGo to the performance trend section. How to compare your records with ours is there.

On this pageBefore you start

Before you start

The check lists

Daily or per shift

  • Scan the stack and the external loop: no electrolyte, water or gas leaking at the ports, the fittings or the cell edges.
  • No white crystals around the ports or fittings, which can be dried KOH.
  • The electrolyte flow and temperature are stable near target.
  • The stack voltage is stable for the current setpoint.
  • The hydrogen outlet and the oxygen and electrolyte return are unobstructed, and the two paths are not mixed.

Weekly

  • Review the records and trends: stack voltage against current, the spread between cells, the stability of flow and temperature, and any recurring abnormal events.
  • Inspect the tubing, fittings and supports for wear, discolouration, crystal residue, weeping leaks, and any load on the ports.
  • Inspect the DC cable routing and the terminal area for discolouration or signs of heat, looseness and corrosion.

Monthly

  • Check the electrolyte condition, and replace it if any criterion in the next section applies.
  • Update the maintenance and operating records: run hours, start-stop cycles, electrolyte replacement dates, observations and corrective actions.

Changing the electrolyte

KOH is not consumed by electrolysis. Water is, and you make that up during operation. The electrolyte is therefore replaced by its condition and the performance trend rather than on a fixed interval. Consider replacing it when any of the following appears.

  • Cell voltage rises continuously at the same current compared with earlier operation.
  • Where you measure individual cells, the spread between them widens over time.
  • The colour or clarity changes, or precipitate appears in the tank or the loop.

The procedure

  1. Perform a normal shutdown and let it cool to a safe temperature by your site practice.
  2. Depressurise the external loop and drain the loop and tank into labelled, alkali-compatible containers.
  3. Dispose of the used electrolyte to regulation and your site procedures.
  4. Make up fresh 0.1 M electrolyte, refill the tank and purge air from the loop.
  5. Restart circulation, check for leaks at every fitting and port, then resume electrolysis.

Cleaning

  • Wipe the exterior with a soft cloth dampened with clean water.
  • Wipe white crystals off with a water-dampened cloth, since KOH is water-soluble, then wipe again with clean water and dry.
  • Deal with a spill by your site spill response procedure.

Reading the performance trend

Stack voltage rises over time. The point of watching the trend is to separate gradual change from an abnormal change caused by off-nominal conditions.

  • Record the stack voltage periodically at one or more fixed operating points. Conditions that change every time give you noise, not a trend.
  • If you can measure individual cell voltages, record the spread between cells too. A widening spread matters even when the average holds.
  • Keep the run hours, start-stop cycles, setpoints and any abnormal events with it.
What you seeWhat it means
A step change at constant currentAbnormal. Start with the order of checks in the troubleshooting chapter.
A rapid change over a short periodAbnormal either way. If the temperature moves with it, suspect water make-up, concentration and cooling first.
One cell climbing well above the othersAbnormal. Stop operating and contact us with your records.

What this chapter is based on

Resource library →

TroubleshootingA find-by-symptom table, the order of checks, the causes behind odd voltage behaviour, and what to send us.

Ask the engineer who built it

If your case is not covered here, send us the operating condition and what you observed. The engineer who designed the system answers directly.