HydroXpandHandbook

← HXP-an · HXP-ca handbook

Formats and ordering

HXP-an · HXP-ca · updated 2026-11-04

Which of the three standard formats to choose, the conditions behind the published figures, what we make to order, what to put in an order, and lead times.

What you need to decide which format to order. There are two standard formats for different purposes, and anything else is made to order.

The exact dimensions, thickness and catalyst loading are in the full specification table on the product pages. This chapter is only about which row of that table you want.

  • Minimum orderOne sheet · no minimum value
  • Lead timeStandard two weeks · custom approx. four weeks to two months
  • CustomSize and thickness quoted per order
How to read this chapter

First timeDecide the format in the first section, then, if you need something non-standard, see the second section on custom orders.

Done this beforeThe lead time and the minimum order are what you need.

On this pageWhich format to choose

Which format to choose#

FormatWhenWatch for
Anode · laboratory formatFor cutting to the active area you need. This is the large-area, thin one.Being thin, it is less forgiving to handle. Keep it flat.
Anode · stack formatThe format that goes into our own stacks. This is the thick one.Its thickness has to suit your gasket stack-up, which changes the compression.
CathodeOne standard format, with a choice of Pt/C or PtRu/C catalyst.Both cost the same; they differ in behaviour. Pt/C starts lower but lasts longer, and PtRu/C is the reverse.
Size and thickness of the three HXP standard formats. In plan at the same scale, the lab-format anode and the cathode are 200 × 300 mm, close to an A4 sheet (210 × 297 mm), and the stack-format anode is 100 × 100 mm. Magnified, the thicknesses are 300 µm for the lab anode, 260 µm for the cathode and 3.0 mm for the stack anode, so the two anode formats differ nearly tenfold. Other sizes and thicknesses are made to order.
Figure 3-1 Standard formats, size and thickness. Dimensions are from the product page specification table; see it for tolerances.

Made to order#

What we can make
Size and thickness to your specification, quoted per order. The same applies to both anode and cathode.
Minimum order
From a single sheet, with no minimum order value.
Lead time
Two weeks for a standard format and approx. four weeks to two months for a custom one, which takes longer because the substrate has to be brought in first. Tell us early if you have a test schedule.
Inspection before shipment
Dimensions and thickness measured and every piece visually inspected, custom orders included.

What to put in your order#

ItemHow to state it
ElectrodeAnode (HXP-an) or cathode (HXP-ca)
FormatThe format name together with its size and thickness. A name on its own costs an extra round of confirmation
Cathode catalystPt/C or PtRu/C. If you have not decided, say so
QuantityThe number of sheets. If you will cut them, add the piece size and count and we will work out how many standard sheets that takes
If customLength, width and thickness
Where it will runWhether the electrolyte is alkaline or something else
ScheduleThe date your testing starts

What this chapter is based on

Resource library →

TroubleshootingDamage on arrival, a leaking cell, numbers that differ from the datasheet: what to check first, and what to send us.
Was this page helpful?

Ask the engineer who built it

If your case is not covered here, send us the operating condition and what you observed. The engineer who designed the system answers directly.